| Technical characteristics of the ceramic discs | |||
|---|---|---|---|
| Material | AL2O3 92%~96% | ||
| Surface roughness | Ra 0.1 ~ Ra 0.3 μm | ||
| Hardness | >1000 HV | ||
| Flatness | <0.6 μm | ||
| Technical characteristics of the cartridge | |||
| Max. opening angle | 24.5° | ||
| Max. rotary angle | 90° | ||
| Recommended nut tightening torque | 10~12 N.m | ||
| Water resistance pressure | 500 psi | ||
| Max. temperature | 82.2℃(179.96℉) | ||
| Endurance test | 500,000 cycles (ASME A112.18.1) | ||
| Flow rate | |||
| Water pressure | Hot (L/min) |
Cold (L/min) |
Mixing (L/min) |
| 1 bar | 9.04 | 9.02 | 12.32 |
| 2 bar | 12.26 | 12.48 | 17.08 |
| 3 bar | 14.86 | 15.12 | 20.82 |

♦ We recommend using running water with a filter in the inlet pipe.
♦ To ensure the best utility of the thermostatic cartridge, please follow our recommended inlet temperature:
Cold water 10°C~15°C / Hot water 60°C~65°C
♦ Appropriately use with a check valve.
♦ All surfaces inside the faucet must be clean. No swarf or other pollutions.